ELECTRICAL SYSTEM 16-35
Charging System
Regulator/Rectifier Inspection
•
Remove the Bolts [A].
•
Disconnect the connectors [A].
•
Remove the regulator/rectifier [B].
•
Set the hand tester to the × 1 kΩ range and make the
measurements shown in the table.
Special Tool - Hand Tester: 57001-1394
•
Connect the hand tester to the regulator rectifier.
If the tester readings are not as specified, replace the
regulator/rectifier.
CAUTION
Use only Kawasaki Hand Tester 57001-1394 for this
test. A tester other than the Kawasaki Hand Tester
may show different readings.
If a megger or a meter with a large capacity battery
is used, the regulator/rectifier will be damaged.
Regulator/Rectifier Resistance (Unit: kΩ)
Tester (+) Lead Connection
Term inal W BK1 BK2 BK3
BK/Y
W
–
20 ∼ 300 20 ∼ 300 20 ∼ 200 20 ∼ 750
BK1 0 ∼ 5
–
20 ∼ 300 20 ∼ 200 20 ∼ 750
BK2 0 ∼ 5 20 ∼ 300
–
20 ∼ 200 20 ∼ 750
BK3 0 ∼ 5 20 ∼ 300 20 ∼ 300
–
20 ∼ 750
(–)*
BK/Y
5 ∼ 20 5 ∼ 20 5 ∼ 20 5 ∼ 20
–
(−)*: Tester (−) Lead Connection
•
Install the regulator/rectifier.
Torque - Regulator/Rectifier Bolts: 10 N·m (1.0 kgf·m, 89
ft·lb)