9-18 CRANKSHAFT/TRANSMISSION
Crankshaft and Connecting Rods
CAUTION
The connecting rod bolts are designed to stretch
when tightened. Never reuse the connecting rod
bolts. See the table below for correct bolt and nut
usage.
CAUTION
Be careful not to overtighten the nuts.
The bolts must be positioned on the seating surface
correctly to prevent the bolt heads from hitting the
crankcase.
(1) Bolt Length Measurement Method
Be sure to clean the bolts, nuts, and connecting rods
thoroughly with a high-flash point solvent, because the
new connecting rods, bolts, and nuts are treated with an
anti-rust solution.
WARNING
Clean the bolts, nuts, and connecting rods in a well
-ventilated area, and take care that there is no spark
or flame anywhere near the working area. This in-
cludes any appliance with a pilot light. Because of
the danger of highly flammable liquids, do not use
gasoline or low-flash point solvents to clean them.
CAUTION
Immediately dry the bolts and nuts w ith com-
pressed air after cleaning.
Clean and dry the bolts and nuts completely.