Kawasaki Brute Force 750 4x4i Offroad Vehicle User Manual


 
17-68 ELECTRICAL SYSTEM
Meter
Check 12: Meter Illumination Check
Connect the wires in the same manner as Check 1.
Connect terminal [6] to battery (+) terminal.
The meter illumination [A] should go on.
If the illumination does not go on, replace the meter unit.
Check 13: Belt Check Indicator Light check
Connect the wires in the same manner as Check 1.
Connect terminal [2] to the battery (–) terminal.
The belt check indicator light (LED) [A] should go on.
It the LED does not go on, replace the meter unit.
Drive Belt Failure M ode Memory Clearing Procedure
A flashing BELT check indicator LED (Light Emitting
Diode) light means that the drive belt failure detection
system has activated. The belt check indicator light will
illuminate and stay on when activated by the 100 hour belt
check system.
NOTE
Follow the instruction on page 2-25 of this Service Man-
ual to complete the necessary inspections.
After completing the inspections, follow these instruc-
tions to clear the system memory and turn off the light.