17-64 ELECTRICAL SYSTEM
Meter
Check 2: MODE and TIME SET Buttons Operation
Check
•
Connect the wires in the same manner as Check 1.
•
Check that when the MODE button [A] is pushed and
held continuously, the display [B] cycles through the four
modes.
ODO → TRIP A → TRIP B → Hour → ODO
If this display function does not work, replace the meter
unit.
•
Cycle the meter to TRIP A or TRIP B mode.
•
Check that when the SET/RESET button [A] is pushed,
the display turns to 0.0.
If this display function does not indicate 0.0 [B], replace
the m eter unit.
•
Check that when the TIME SET [A] and S ET/RE SET [B]
buttons are pushed, the time [C] will reset.
If the meter function does not work, replace the meter unit.
Check 3: Speedometer Check
•
Connect the wires in the same manner as Check 1.
•
The speed equivalent to the input frequency is indicated in
the oscillator [A], if the square wave is input into terminal
[1].
○
Indicates approximately 40 mph if the input frequency is
approximately 789 Hz.
○
Indicates approximately 40 km/h if the input frequency is
approximately 526 Hz.
If the meter function does not work, replace the meter unit.