Kawasaki Brute Force 750 4x4i Offroad Vehicle User Manual


 
17-24 ELECTRICAL SYSTEM
Battery
Charging Condition Inspection
Battery charging condition can be checked by measuring
battery terminal voltage.
Remove the battery (see Battery Removal).
CAUTION
Be sure to disconnect the negative () lead first.
Measure the battery terminal voltage.
NOTE
Measure with a digital voltmeter [A] which can be read
to one decimal place voltage.
If the reading is below the specified, refreshing charge is
required.
Battery Terminal Voltage
Standard: 12.8 V or more
Refreshing Charge
Remove the battery [A] (see Battery Removal).
Refresh-charge by following method according to the bat-
tery terminal voltage.
WARNING
This battery is sealed type. Never remove seal
sheet [B] even at charging. Never add water.
Charge with current and time as stated below.
Terminal Voltage: 11.5 less than 12.5 V
Standard Charge
1.2 A × 5 10 h (see following chart)
Quick Charge
6.0 A × 1.0 h
CAUTION
If possible, do not quick charge. If the quick charge
is done due to un avoidable circumstances, do the
standard charge later on.
Terminal Voltage: less than 11.5 V
Charging Method: 1.2 A × 20 h