PAIR (AIRSUPPLY) SYSTEM INSPECTION
HOSES
Inspect the hoses for wear or damage.
Inspect that the hoses and pipes are securely connected.
PAIR REED VALVE
Remove the PAIR reed valve cover.
Inspect the reed valve for the carbon deposit.
If the carbon deposit is found in the reed valve, replace the
PAIR reed valve with a new one.
PAIR CONTROL VALVE
Check that air flows through the PAIR control valve air inlet
port to the air outlet ports.
If air does not flow out, replace the PAIR control valve with a
new one.
Connect the vacuum pump gauge to the vacuum port of the
control valve as shown in the photograph.
Apply negative pressure of the specification slowly to the con-
trol valve and inspect the air flow.
If air does not flow to the pump, the control valve is in normal
condition.
If the control valve does not properly function within the speci-
fication, replace the control valve with a new one.
_ Negative pressure range: More than 66.6 kPa
(491 mmHg)
S 09917-47010: Vacuum pump gauge
ICAUTION I
Use a hand operated vacuum pump to prevent the
control valve damage.