EXCVA ADJUSTMENT
1st step:
• Set the EXCVA to adjustment position. (c:::::r6-4)
• Make sure that the
NO.2
cable and
NO.1
cable are fixed into
the clamp.
2nd step:
• Turn the mode select switch OFF.
• Turn the ignition switch ON to check the EXCVA operation.
• Turn the mode select switch ON.
• If C46 is not indicated on the LCD (DISPLAY), the adjustment
is correctly completed. In this case, it is unnecessary to pro-
ceed to 3rd step.
• If C46 is indicated, repeat the adjustment procedure from 3rd
and 4th step.
3rd step:
• This procedure is only required when C46 is indicated.
• Turn the ignition switch
OFF.
• Insert the two copper wires into the back side of the position
sensor lead wire coupler
CD.
• Disconnect the EXCVA motor lead wire coupler
(2).
EXHAUST
SYSTEM
6-9