ELECTRICAL
SYSTEM
9·23
Peak
volt
adaptor
CKP sensor
coupler
Q
~
G
CKP sensor
B--'----f"'"~
If the peak voltage is lower than the standard range, check the
peak voltage at the CKP sensor lead wire coupler.
• Lift up the fuel tank.
(c::::.rS-S)
• Disconnect the CKP sensor lead wire coupler and connect the
multi circuit tester with the peak volt adaptor.
Green
(@ Probe) - Black
(8
Probe)
• Measure the CKP sensor peak voltage at the CKP sensor
lead wire coupler.
~
Tester knob indication: Voltage
(=-=-:)
B CKP sensor peak voltage: 0.5 V and more
(Green - Black)
If the peak voltage is lower than the standard range, check each
coupler at both ends of the circuit or replace the CKP sensor
and inspect it again.
CKP SENSOR RESISTANCE
• Measure the resistance between the lead wires and ground. If
the resistance is not as specified, the CKP sensor must be
replaced.
,@tI
09900-25008: Multi circuit tester set
~
Tester knob indication: Resistance
(0)
B CKP sensor resistance: 70 -
2200
(Green - Black)
:
00
0 (Green - Ground)