Suzuki GSX-R1000 Automobile User Manual


 
ELECTRICAL
SYSTEM
9·23
Peak
volt
adaptor
CKP sensor
coupler
Q
~
G
CKP sensor
B--'----f"'"~
If the peak voltage is lower than the standard range, check the
peak voltage at the CKP sensor lead wire coupler.
Lift up the fuel tank.
(c::::.rS-S)
Disconnect the CKP sensor lead wire coupler and connect the
multi circuit tester with the peak volt adaptor.
Green
(@ Probe) - Black
(8
Probe)
Measure the CKP sensor peak voltage at the CKP sensor
lead wire coupler.
~
Tester knob indication: Voltage
(=-=-:)
B CKP sensor peak voltage: 0.5 V and more
(Green - Black)
If the peak voltage is lower than the standard range, check each
coupler at both ends of the circuit or replace the CKP sensor
and inspect it again.
CKP SENSOR RESISTANCE
Measure the resistance between the lead wires and ground. If
the resistance is not as specified, the CKP sensor must be
replaced.
,@tI
09900-25008: Multi circuit tester set
~
Tester knob indication: Resistance
(0)
B CKP sensor resistance: 70 -
2200
(Green - Black)
:
00
0 (Green - Ground)