• Remove the clamp
CD.
• Disconnect the
NO.2
cable
(2)
and then
NO.1
cable @ from the
pulley.
• Disconnect the EXCVA lead wire couplers
@.
• Remove the EXCVA.
EXCVA can also be removed in the following procedures.
• Remove the front footrest
@.
• Disconnect the EXCV cable.
(L7"6-12)
• Remove the EXCVA mounting bolt.
(L7"6-4)
• Remove EXCVA, cable and EXCV together as a unit.
EXCVA INSTALLATION
Install the EXCVA in the reverse order of removal. Pay attention
to the following points:
• Connect the
NO.1
cable
CD
(Black chrome plated adjuster)
and NO.2 cable
(2)
(Silver chrome plated adjuster) to the
EXCVA pulley.
• After connecting the
NO.2
cable
(2),
loosen the lock-nut @ and
turn the adjuster
@ in or out until 11.0 mm (0.43 in) and more
of the thread length
® on the cable adjuster can be provided
and tighten the lock-nut
@.
EXHAUST
SYSTEM
6·5