FI SYSTEM DIAGNOSIS 4-37
.
Is the voltage OK?
3) After repairing the trouble, clear the DTC using SDS tool.
(4-27)
YES
• G/W or O/BI wire open or shorted to ground.
• Loose or poor contacts on the CKP sensor cou-
pler or ECM coupler (terminal D or U).
• If wire and connection are OK, intermittent trou-
ble or faulty ECM.
• Recheck each terminal and wire harness for
open circuit and poor connection.
• Replace the ECM with a known good one, and
inspect it again.
NO
• Inspect that metal particles or foreign material
stuck on the CKP sensor and rotor tip.
• If there are no metal particles and foreign mate-
rial, then replace the CKP sensor with a new
one.
When using the multi-circuit tester, do not storongly
touch the terminal of the ECM coupler with a needle
pointed tester probe to prevent the terminal damage
or terminal bend.
2
(Black) (Gray)
ECM couplers (Harness side)