3-16 FUEL SYSTEM (DFI)
DFI Servicing Precautions
○
Whenever the DFI electrical connections are to be discon-
nected, first turn off the ignition SW (switch), and discon-
nect the battery (–) terminal. Do not pull the lead, only the
connector. Conversely, make sure that all the DFI elec-
trical connections are firmly reconnected before starting
the engine.
○
When disconnecting the vehicle-down sensor connector,
raise the lock of the connector. Push the lock of the other
connectors.
○
To maintain the correct fuel/air mixture (F/A), there must
be no inlet air leaks in the DFI system. Be sure to install
the oil filler plug [A] after filling the engine oil.
Clutch Cover [ B]
Torque - Oil Filler Plug: 1.5 N·m (0.15 kgf·m, 13 in·lb)