ELECTRICAL SYSTEM 16-69
Meter, Gauge, Indica tor Unit
Water Temperature Meter Check:
•
Connect the 12 V battery and terminals in the same man-
ner as specified in the "Liquid Crystal Display (LCD) Seg-
ments Check".
•
Connect the variable r heostat [A] to the terminal [8] as
shown.
•
Check that the number of segments matches the resis-
tance value of the variable rheostat.
Resistance Temperature Warning
Value (Ω)
Meter Indicate
–
[A] –
209.8
50°C (122°F)
[B] –
69.1
80°C (176°F)
[B] –
21.2
120°C (248°F) [C] Flash
17 HI [D] Flash
•
If any display function does not work, replace the meter
assembly.