FUEL SYSTEM (DFI) 3-45
Inlet Air Pressure Se nsor (Service Code 12)
then
Pv = Pl – Pg
For example, suppose the following data is obtained:
Pg = 8 cmHg (vacuum gauge reading)
Pl = 70 cmHg (barometer reading)
Vv = 3.2 V (digital volt meter reading)
then
Pv=70–8=62cmHg(abs)
Plot this Pv (62 cmHg) at a point [1] on the chart and draw a vertical line through the point. Then, you
can get the usable range [2] of the sensor output voltage.
Usable range = 3.04 ∼ 3.49 V
Plot Vv (3.2 V) on the vertical line. → Point [3].
Results: In the chart, Vv is within the usable range and the sensor is normal.
Pv = 24 ∼ 55 cmHg