16-64 ELECTRICAL SYSTEM
Meter, Gauge, Indicator Unit
Meter Unit Removal
•
Remove:
Fairing (see Frame chapter)
•
Slide the dust cover [A] and remove the wiring connector
[B].
•
Remove the meter unit by taking off the mounting screws
[C] with the washers.
CAUTION
Place the meter or gauge so that the face is up. If a
meter or gauge is left upside down or sideways for
any length of time, it will malfunction.
Meter, Gauge Disassembly
•
Remove:
Meter Unit (see Meter Unit Removal)
Screws [A]
Lower Meter Cover [B]
•
Separate the m eter assembly [A] and upper meter cover
[B].