48
Reference Manual
00809-0100-4444, Rev AC
Section 3: Advanced Installation Details
January 2015
Advanced Installation Details
Figure 3-7. Connecting to an Electronic Totalizer/Counter with External Power Supply
Note
Total loop impedance must be sufficient to keep loop current below maximum rating.
5-24 V DC
Power Supply
Schematic showing
FET between
terminal 3 and 4
Electronic
Counter