Appendix A: Implementing a Universal Transmitter
January 2015
Implementing a Universal Transmitter
A.12 Yokogawa sensors
Connect coil drive and electrode cables as shown in Figure A-22.
A.12.1 Yokogawa sensor to Rosemount 8732 transmitter
Figure A-22. Generic Wiring Diagram for Yokogawa Sensors and Rosemount 8732
Table A-23. Yokogawa Sensor Wiring Connections
Rosemount 8732 Yokogawa sensors
1 EX1
2 EX2
3 Chassis Ground
17 C
18 B
19 A
Do not connect mains or line
power to the magnetic flowtube
sensor or to the transmitter coil
excitation circuit.
Electrodes
Coils
Chassis Ground
ROSEMOUNT 8732
TRANSMITTER
YOKOGAWA
SENSORS
Ex 2
Ex 1
A
B
C
Refer to Figure A-1 on page 174 for
actual terminal block configuration
drawing.
1
2
17
18
19
3