B.1.2 Advanced diagnostics capabilities
Basic
Self test
Transmitter faults
Analog output test
Pulse output test
Tunable empty pipe
Reverse flow
Coil circuit fault
Electronics temperature
Process diagnostics (DA1)
Ground/wiring fault
High process noise
Electrode coating diagnostic
Smart meter verification (DA2)
SMART
Meter Verification (continuous or on-demand)
4-20mA loop verification
B.1.3 Output signals
Analog output adjustment
(1)
4–20mA, switch-selectable as internally or externally powered.
Analog loop load limitations
Internally powered 24VDC max, 500 ohms max loop resistance
Externally powered 10.8 - 30VDC max.
Loop resistance is determined by the voltage level of the external power supply at the
transmitter terminals.
(1) For transmitters with intrinsically safe outputs (option code B), power must be supplied externally.