Emerson 00809-0100-4444 Automobile Parts User Manual


 
208
Reference Manual
00809-0100-4444, Rev AC
Appendix B: Product Specifications
January 2015
Product Specifications
Other manufacturers’ sensors
When calibrated in the Rosemount Flow Facility, system accuracies as good as 0.5% of rate can
be attained.
There is no accuracy specification for other manufacturers’ sensors calibrated in the process
line.
B.1.6 Analog output effects
Analog output has the same accuracy as frequency output plus an additional ±4A at room
temperature.
Repeatability
±0.1% of reading
Response time (analog output)
20 ms max response time to step change in input
Stability
±0.1% of rate over six months
Ambient temperature effect
±0.25% change over operating temperature range
B.1.7 Physical specifications
Materials of construction
Standard housing
Low copper aluminum
Type 4X and IEC 60529 IP66
Paint
Polyurethane coat (1.3 to 5 mils thick)
Optional housing
316/316L unpainted, option code SH
Type 4X and IEC 60529 IP66
Cover gasket
Buna-N