142
Reference Manual
00809-0100-4444, Rev AC
Section 8: Maintenance
January 2015
Maintenance
Figure 8-6. Socket Module—Integral Mount
Removing integral mount socket module
1. Disconnect power.
2. Remove electronics cover to gain access to the coil and electrode cables.
3. If the transmitter has an LOI, it will need to be removed to gain access to the coil and
electrode cables.
4. Disconnect the coil and electrode cables.
5. Remove the four transmitter mounting screws.
6. Lift the transmitter off of the sensor adapter.
7. To remove the socket module, loosen the two mounting screws and pull up on the
socket module from the base.
8. When removing the socket module, do not pull on the wires. See Figure 8-5.
Installing integral mount socket module
1. To insert a new integral mount socket module, press the base into its keyed position
and tighten the two mounting screws.
2. The coil and electrode cables are fed through the bottom opening of the transmitter
and plugged into the face of the electronics.
3. The coil and electrode cables are keyed so they will only fit into their dedicated location.
4. If the transmitter has an LOI, it will need to be removed to access the coil and electrode
ports.
5. Once the connections are made, the transmitter can be secured to the sensor adapter
using the four mounting bolts.