186
Reference Manual
00809-0100-4444, Rev AC
Appendix A: Implementing a Universal Transmitter
January 2015
Implementing a Universal Transmitter
A.6 Foxboro sensors
Connect coil drive and electrode cables as shown in Figure A-12.
A.6.1 Series 1800 sensor to Rosemount 8732 transmitter
Figure A-12. Wiring Diagram for Foxboro Series 1800 and Rosemount 8732
Table A-13. Foxboro Series1800 Sensor Wiring Connections
Rosemount 8732 Foxboro Series 1800 sensors
1 L1
2 L2
3 Chassis Ground
17 Any Shield
18 Black
19 White
Do not connect mains or line power to the
magnetic flowtube sensor or to the transmitter
coil excitation circuit.
1
2
17
18
19
3
ROSEMOUNT 8732
TRANSMITTER
Coil Connections
Electrode Connections
FOXBORO SERIES 1800
SENSOR
Outer Shield
White Lead
White Shield
Black Lead
Black Shield
Inner Shield
Refer to Figure A-1 on page 174 for actual
terminal block configuration drawing.