00809-0100-4444, Rev AC
Appendix C: Approval Information
January 2015
Approval Information
Rosemount 8700M Magnetic Flowmeter Platform
IEC EX & ATEX Approval Document
December 15, 2014,
08732-AP02, Rev AA
Nomenclature Magnetic Flow Tube Model 8711-M/L and electrical data
8711
S A 15F L K1 G1 J1 SC V1 F090x
I II III IV V VI VII VIII IX X XI
Designation
Explanation
Value Explanation
I Model 8711 Magnetic Flow Tube
II Electrode Material Custom See special conditions for safe use
III Electrode Types Custom Seal of electrodes comply with IEC 61010-1.
IV Line Size
015
to
080
1½” NPS (40 mm)
to
8” NPS (900 mm)
V
Mounting
Configuration
L
M
Remote Mount from Transmitter
Integral Mount with Transmitter
VI Safety Approvals
K1
ATEX
II 2 G Ex e ib IIC T5…T3 Gb
II 2 D Ex tb IIIC T 80 °C…T 200 °C Db
K7 IECEx
Ex e ib IIC T5…T3 Gb
Ex tb IIIC T 80 °C…T 200 °C Db
N1 ATEX
II 3 G Ex nA ic IIC T5…T3 Gc
II 2 D Ex tb IIIC T 80 °C…T 200 °C Db
N7 IECEx
Ex nA ic IIC T5…T3 Gc
Ex tb IIIC T 80 °C…T 200 °C Db
ND ATEX II 2 D Ex tb IIIC T 80 °C…T 200 °C Db
NF IECEx Ex tb IIIC T 80 °C…T 200 °C Db
VII
Grounding rings
material
Custom See special conditions for safe use
VIII
Optional conduit
entries
J1 CM20, M20 female
IX
Remote Junction
Box material
--
SC
Aluminum, Standard Paint *
316 Stainless Steel *
NOTE:* Flowtube with Carbon Steel Wrapper (housing)
X
Special paint
options
Vx Special Paint Systems **
XI Specials F090x Special Paint Systems **