Emerson 00809-0100-4444 Automobile Parts User Manual


 
Reference Manual
00809-0100-4444, Rev AC
Appendix B: Product Specifications
January 2015
199Product Specifications
Appendix B Product Specifications
Rosemount 8732EM Transmitter specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 199
Rosemount 8705-M Flanged Sensor specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 210
Rosemount 8711-M/L Wafer Sensor specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 216
Rosemount 8721 Hygienic (Sanitary) Sensor specifications . . . . . . . . . . . . . . . . . . . . . . . page 220
B.1 Rosemount 8732EM Transmitter specifications
B.1.1 Functional specifications
Sensor compatibility
Compatible with Rosemount 8705, 8711, and 8721 sensors. Compatible with AC and DC
powered sensors of other manufacturers.
Transmitter coil drive current
500mA
Flow rate range
Capable of processing signals from fluids that are traveling between 0.04 and 39 ft/s (0.01 to 12
m/s) for both forward and reverse flow in all sensor sizes. Full scale continuously adjustable
between –39 and 39 ft/s (–12 to 12 m/s).
Conductivity limits
Process liquid must have a conductivity of 5 microSiemens/cm (5 micromhos/cm) or greater.
Power supply
90 - 250VAC, 50/60Hz or 12 - 42VDC