Emerson 00809-0100-4444 Automobile Parts User Manual


 
126
Reference Manual
00809-0100-4444, Rev AC
Section 6: Advanced Diagnostics Configuration
January 2015
Advanced Diagnostics Configuration
Coil signature
The coil signature is a measurement of the magnetic field strength. This value is compared to the
coil signature baseline measurement taken during the sensor signature process to determine
sensor calibration deviation. This value can be continuously monitored using continuous SMART
Meter Verification.
Electrode circuit resistance
The electrode circuit resistance is a measurement of the electrode circuit health. This value is
compared to the electrode circuit resistance baseline measurement taken during the sensor
signature process to determine electrode circuit health. This value can be continuously
monitored using continuous SMART Meter Verification.
Actual velocity
The actual velocity is a measurement of the simulated velocity signal. This value is compared to
the simulated velocity to determine transmitter calibration deviation. This value can be
continuously monitored using continuous SMART Meter Verification.
LOI menu path
Manual: Diagnostics, Advanced Diag, Meter Verify, Measurements, Manual
Measure, Coil Inductnce
Continuous: Diagnostics, Advanced Diag, Meter Verify, Measurements,
Continual Meas, Coil Inductnce
Traditional fast keys Manual: 1,2,3,2,5,1,2
Continuous: 1,2,3,2,5,2,2
Device dashboard Manual: 3,4,1,3,2
Continuous: 3,2,4,2,2
LOI menu path
Manual: Diagnostics, Advanced Diag, Meter Verify, Measurements, Manual
Measure, Electrode Res
Continuous: Diagnostics, Advanced Diag, Meter Verify, Measurements,
Continual Meas, Electrode Res
Traditional fast keys
Manual: 1,2,3,2,5,1,3
Continuous: 1,2,3,2,5,2,3
Device dashboard
Manual: 3,4,1,3,3
Continuous: 3,2,4,2,4
LOI menu path
Manual: Diagnostics, Advanced Diag, Meter Verify, Measurements, Manual
Measure, Actual Velocity
Continuous: Diagnostics, Advanced Diag, Meter Verify, Measurements,
Continual Meas, Actual Velocity
Traditional fast keys Manual: 1,2,3,2,2,1,5
Continuous: 1,2,3,2,5,2,4
Device dashboard Manual: 3,4,1,5,3,2
Continuous: 3,2,4,3,2