Emerson 00809-0100-4444 Automobile Parts User Manual


 
195
Reference Manual
00809-0100-4444, Rev AC
Appendix A: Implementing a Universal Transmitter
January 2015
Implementing a Universal Transmitter
A.11 Yamatake Honeywell sensors
Connect coil drive and electrode cables as shown in Figure A-21.
A.11.1 Yamatake Honeywell sensor to Rosemount 8732
transmitter
Figure A-21. Generic Wiring Diagram for Yamatake Honeywell Sensors and Rosemount
8732
Table A-22. Yamatake Honeywell Sensor Wiring Connections
Rosemount 8732 Yamatake Honeywell sensors
1 X
2 Y
3 Chassis Ground
17 C
18 B
19 A
Do not connect mains or line power to the
magnetic flowtube sensor or to the transmitter
coil excitation circuit.
Electrodes
Coils
Chassis Ground
ROSEMOUNT 8732
TRANSMITTER
YAMATAKE
HONEYWELL
SENSORS
Y
X
A
B
C
Refer to Figure A-1 on page 174 for actual terminal
block configuration drawing.
1
2
17
18
19
3