188
Reference Manual
00809-0100-4444, Rev AC
Appendix A: Implementing a Universal Transmitter
January 2015
Implementing a Universal Transmitter
A.6.3 Series 2800 Sensor to 8732 Transmitter
Connect coil drive and electrode cables as shown in Figure A-14.
Figure A-14. Wiring Diagram for Foxboro Series 2800 and Rosemount 8732
Table A-15. Foxboro Series 2800 Sensor Wiring Connections
Rosemount 8732 Foxboro Series 2800 Sensors
1 L1
2 L2
3 Chassis Ground
17 Any Shield
18 Black
19 White
Do not connect mains or line power to the
magnetic flowtube sensor or to the transmitter
coil excitation circuit.
1
2
17
18
19
3
ROSEMOUNT 8732
TRANSMITTER
Coil Connections
Electrode Connections
FOXBORO SERIES 2800
SENSOR
Outer Shield
White Lead
White Shield
Black Lead
Black Shield
Inner Shield
White
Black
Any Shield
L2
L1
G
Refer to Figure A-1 on page 174 for
actual terminal block configuration
drawing.