E-3
Power Source
• Make sure that the power switch is set to OFF (“ ”) when the CM-700d/600d is not in use.
• The CM-700d/600d can be powered from either the AC adapter (AC-A305) or AA-size alkaline or nickel-
metal-hydride rechargeable batteries. Note, however, that you cannot use this AC adapter to charge the nickel-
metal-hydride rechargeable batteries installed in the instrument.
• Always use the AC adapter supplied as a standard accessory (AC-A305) and connect it to an AC outlet of the
rated voltage and frequency. Use an AC power supply of the rated supply voltage (within ±10%).
System
• Do not subject the CM-700d/600d to strong impact or vibration. Doing so may cause deterioration in
performance or a breakdown.
• Since the specimen measuring port and integrating sphere are extremely precise optical components, great
care should be taken to prevent them getting dirty or exposing them to impact.
• When not in use, the instrument must be stored with the White Calibration Cap being attached.
• The CM-700d/600d may cause interference if used near a television, radio, etc.
• When the instrument is exposed to strong external static electricity, the LCD may go blank or the measurement
result may not be displayed properly. If the instrument is communicating with an external device, the
communication may be interrupted. In these cases, turn the power OFF and then turn it ON again. If black
smudges appear on the LCD, wait until they disappear naturally.
• When turning the power OFF and then ON again, wait several seconds after turning the power OFF.
Backup Battery
• Measured data and various settings are stored in the memory backed up by batteries. The backup batteries are
automatically charged during operation of this instrument, and can retain the contents of the memory for 5
months if they have been fully charged. At the time of purchase, the backup battery may not be fully charged.
To charge the backup battery, set the power switch to ON. Charging of the backup battery is performed
continuously while the instrument is switched on, even while the instrument is being used. Full charging is
completed in 24 hours, and there is no danger of overcharging.
• It is recommended to keep a backup for your important data on another recording medium using the optional
Color Data Software SpectraMagic™ NX (CM-S100w).
Note
• The backup batteries' model number is ML2020 (3 V).
• Do not try to replace the backup batteries by yourself. Contact a KONICA MINOLTA-authorized service
facility.
Notes on Storage
• The CM-700d/600d should be stored at temperatures between 0°C and 45°C, and at a relative humidity of 80%
or less (35°C) without condensation. Do not store the instrument in areas subject to high temperatures, high
humidity, sudden changes in temperature, or where freezing or condensation may occur, because these
circumstances may cause a breakdown. It is recommended to store the CM-700d/600d with a drying agent at
a temperature around 20°C.
• Do not leave the CM-700d/600d inside a car such as in the cabinet or trunk. Otherwise, the temperature and/
or humidity may exceed the allowable range for storage during midsummer or midwinter, resulting in a
breakdown.
• Keep the packing materials used for shipment and use them to transport the CM-700d/600d. This protects the
instrument from sudden changes in temperature, vibration, and shock.
• Do not store the CM-700d/600d in areas where dust, cigarette smoke or chemical gases are present. Doing so
may cause deterioration in performance or a breakdown.
• Entry of dust into the specimen measuring port will hinder accurate measurement. When the instrument is not
in use, you must attach the White Calibration Cap to the instrument to prevent the entry of dust into the
integrating sphere through the specimen measuring port.