Konica Minolta ML2020 Automobile Parts User Manual


 
E-8
Conventions
This manual describes how to safely operate the CM-700d/600d using a specific procedure to perform
measurement.
Page layout
Symbols used in this manual are explained below.
*Note that the page shown in the illustration is for explanatory purposes only, and is not an actual page
from this manual.
For the version of the instrument firmware
The version of the instrument firmware can be confirmed on the <Instrument> screen. For details, refer
to page E-117 “Displaying the Instrument Information” in this manual.
E-32
Condition Setting
The CM-700d/600d requires condition settings (display and measurement conditions) before
measurement can be started.
M
emo
To configure condition settings, select “Disp. Cond.” (display conditions) or “Meas. Cond.” (measurement
conditions) from the <Option> screen to open an appropriate screen.
N
ote
The results for “Difference”, “Abs. & Diff.”
and
Graph Diff.
will be displayed only when the target color has been
specified.
Setting the Display Conditions
To set the display conditions, select “Disp. Cond.” on the <Option> screen.
You can select or specify the following seven items as the display conditions:
• Disp. Type: Specify items to be displayed as measurement results.
• Color Space: Select a color space to be used.
• Equation: Select a color difference formula to be used.
• Color Index: Select an index (WI, YI, etc.) to be used.
• Observer: Select a measuring angle from 2° or 10°
• Illuminant 1: Select an illuminant used to measure colorimetric data.
• Illuminant 2: Select a secondary illuminant used for MI (metamerism index) calculation, etc.
[Setting Procedure]
Start the procedure from the <Disp. Cond.> screen.
1
Hold down the [MENU] button and press the
button of the cross key.
The <Option> screen is displayed.
2
Use the
or
button of the cross key to
move the cursor to "Disp. Cond." and then
press the [SAVE/SEL] button.
The <Disp. Cond.> screen is displayed.
Settings
Absolute: Display the absolute value of the colorimetric data.
Difference:
Display the color difference from the target color. The measured data which failed the pass/fail judgment
based on the specified tolerances will be highlighted in red.
Abs. & Diff.:
Display the absolute value and the color difference from the target color. The measured data which
failed the pass/fail judgment based on the specified tolerances will be highlighted in red.
Note
Gives the points that
you should know to
perform operations
correctly. Make sure
that you read the notes.
M
emo
Gives useful
Information and
additional
explanations.
Procedure
Shows the operating
procedure.
Start screen
Shows the screen
from which
operation must
be started.
Screen
Shows the
contents of the
current screen
when the given
operation is
carried out.
Settings
Gives the range and
explanation of the
values to be set in this
screen.