ELECTRICAL
10.28
*NOTE: New Battery: Battery must be fully charged
before use or battery life will be significantly reduced
10-30% of the battery’s full potential.
To activate a new battery:
1. Remove vent plug from vent fitting. Remove cell
caps.
2. Fill battery with electrolyte to upper level marks on
case.
3. Set battery aside to allow for acid absorption and
stabilization for 30 minutes.
4. Add electrolyte to bring level back to upper level
mark on case. NOTE: This is the last time that
electrolyte should be added. If the level becomes
low after this point, add only distilled water.
5. Charge battery at 1/10 of its amp/hour rating.
Examples: 1/10 of 9 amp battery = .9 amp; 1/10
of 14 amp battery = 1.4 amp; 1/10 of 18 amp
battery = 1.8 amp (recommended charging
rates).
6. Check specific gravity of each cell with a
hydrometer to assure each has areading of 1.270
or higher.
BATTERY
TERMINALS/TERMINAL BOL
TS
Use Polaris corrosion resistant Dielectric Grease (PN
2871329) on battery bolts. SeeBattery Installationon
Page 10.27.
CONVENTIONAL BATTERY
INSPECTION/REMOV
AL
The battery is located under the seat and right rear
fender.
Battery Location
Inspect the battery fluid level. When the battery fluid
nears the lower level, remove the battery and fill with
distilled water only
to the upper level line. To remove
the battery:
Maintain
between upper
and lower level
marks
1. Disconnect holder strap and remove covers.
2. Disconnect battery negative (-) (black) cable first,
followed by the positive (+) (red) cable.
CAUTION
Whenever removing or reinstalling the battery,
disconnect the negative (black) cable first and
reinstall the negative cable last!
3. Remove the battery.
4. Remove the filler caps and add distilled water
only as needed to bring each cell to the proper
level. Do not overfill the battery.
Refill using only distilled water. Tap water
contains minerals which are harmful to a battery.
Do not allow cleaning solution or tap water inside
the battery. Battery life may be reduced.
5. Reinstall the battery caps.
CONVENTIONAL BATTERY
INSTALLA
TION
1. Clean battery cables and terminals with a stiff wire
brush. Corrosion can be removed using a solution
of one cup water and one tablespoon baking soda.
Rinse well with clean water and dry thoroughly.
2. Route the cables correctly.
3. Reinstall battery, attaching positive (+) (red) cable
first and then the negative (-) (black) cable. Coat
terminals and bolt threads with Dielectric Grease
(PN 2871329).