Emerson Process Management 3095FC Automobile Accessories User Manual


 
Reference Manual
00809-0100-4832, Rev AA
October 2004
Rosemount 3095FC
3-38
Collect Data Select 3095FC > Collect Data to save various 3095FC data to disk files.
Select the values to be saved for later generating into a report(s). This screen
may only be accessed when the user is on-line with the already configured
3095FC from which data will be gathered.
Use Save As and the Browse button to either accept the default File name or
enter a new File name. The files are saved in the default directory C:/Program
Files/Rosemount User Interface for Windows/Data unless another directory
was selected. When selecting EFM Report Data, the Collect Data function
saves all the values for EFM parameters. The files has the .efm extension.
The EFM Reports utility uses the flow data that was gathered using either the
“EFM Report Data” or the “All” option. The “All” function retrieves Rosemount
User Interface Software data including the EFM Report Data and stores it in
disk files identified with various extensions. The “EFM Report” function
retrieves just the detailed flow data needed for an EFM report and stores it in
disk files with an .AGA extension.
NOTE
EFM Reports can be created, using this data, by selecting View >EFM Report.
Configure History for
EFM Reporting
Electronic Flow Measurement (EFM) Reports
The Rosemount User Interface Software has the ability to create an EFM
report file that contains all the configuration, alarms, events, and history logs
associated with the stations and meter runs. This file becomes the custody
transfer audit trail. To collect the periodic and daily history logs required for the
EFM report file, a specific list of station and meter run parameters must be
configured for historical archiving.
For Orifice meters, the following history points must be configured for EMF
reports.
Table 3-2. Orifice Meter Run History Points
Description Archive Type Point Type Parameter
Flowing Minutes Totalize Orifice Meter Run Values Minutes Accumulated
DP Avg (Flow Dependent Linear)
Avg (Flow Dependent Formulaic)
Avg (Flow Weighted Linear)
Avg (Flow Weighted Formulaic)
Orifice Meter Run Configuration DP
SP Avg (Flow Dependent Linear)
Avg (Flow Dependent Formulaic)
Avg (Flow Weighted Linear)
Avg (Flow Weighted Formulaic)
Orifice Meter Run Configuration SP
Temperature Avg (Flow Dependent Linear)
Avg (Flow Dependent Formulaic)
Avg (Flow Weighted Linear)
Avg (Flow Weighted Formulaic)
Orifice Meter Run Configuration TMP
Pressure Extension Avg (Flow Dependent Linear)
Avg (Flow Dependent Formulaic)
Avg (Flow Weighted Linear)
Avg (Flow Weighted Formulaic)
Orifice Meter Run Configuration Pressure Extension
Multiplier Value Avg (Flow Dependent Linear)
Avg (Flow Dependent Formulaic)
Avg (Flow Weighted Linear)
Avg (Flow Weighted Formulaic)
Orifice Meter Run Configuration Multiplier Value
Volume Totalize Orifice Meter Run Configuration Flow Accumulated
Energy To talize Orifice Meter Run Configuration Energy Accumulated