Emerson Process Management 3095FC Automobile Accessories User Manual


 
Reference Manual
00809-0100-4832, Rev AA
October 2004
3-27
Rosemount 3095FC
AGA Meter Inputs Tab
See Figure 3-20 on page 3-27.
The Inputs tab screen defines the field inputs, including DP and SP to be used
in the flow calculation.
To setup the meter inputs used in the flow calculation:
1. Select Meter > Setup >Input tab.
2. Click the Differential Pressure TLP button to assign the input that
senses the DP (high DP, if Stacked Dp is Enabled). The input units
are inH
2
O (U.S.) or kPa (Metric).
NOTE
If Manual appears, the Values field can be used to enter a value for the meter
input. Otherwise, the Values field indicates the current input value.
3. Click the Static Pressure TLP button to assign the input that senses
the SP. The input units are psig (U.S.) or kPa (Metric).
4. Click the Temperature TLP button to assign the input that senses the
temperature of the flowing gas. The input units are degrees
Fahrenheit (U.S.) or degrees Celsius (Metric).
Figure 3-20. Meter Setup Inputs
Tab Screen