Table C-11. Point Type 17 – Soft Point Parameters
21 R/O BIN 1 ROM Installed – Memory Assignments:
Bit 7 – E0000-FFFFF
Bit 6 – C0000-DFFFF
Bit 5 – A0000-BFFFF
Bit 4 – 80000-9FFFF
Bit 3 – 60000-7FFFF
Bit 2 – 40000-5FFFF
Bit 1 – 20000-3FFFF
Bit 0 – 00000-1FFFF
ROM
22 R/O FLP 4 MPU Loading MPU
23 R/O BIN 1 Utilities:
Bit 7 – Industry Canada Unit
Bit 6 – Not Used
Bit 5 – Not Used
Bit 4 – User Calculation Program Allowed
Bit 3 – COM2 User Program Allowed
Bit 2 – COM1 User Program Allowed
Bit 1 – LCD Installed
Bit 0 – AGA Data archived
UTIL
24 R/O UINT 16 2 Type of device:
3095 = Rosemount 3095
ROCTYPE
25 R/W UINT 8 1 Units Flag
0 = English
1 = Metric (kPa)
2 = Metric (bar)
UNITS
Parameter
Number
Read-
Write
Data Type Length Description Abbr.
Parameter
Number
Read-
Write
Data Type Length Description Abbr.
0 R/W AC 10 Point Tag Identification TAG
1 R/W UINT 16 2 Integer Flag INT1
2 R/W FLP 4 Data #1 DATA1
3 R/W FLP 4 Data #2 DATA2
4 R/W FLP 4 Data #3 DATA3
5 R/W FLP 4 Data #4 DATA4
6 R/W FLP 4 Data #5 DATA5
7 R/W FLP 4 Data #6 DATA6
8 R/W FLP 4 Data #7 DATA7
9 R/W FLP 4 Data #8 DATA8
10 R/W FLP 4 Data #9 DATA9
11 R/W FLP 4 Data #10 DATA10
12 R/W FLP 4 Data #11 DATA11
13 R/W FLP 4 Data #12 DATA12
14 R/W FLP 4 Data #13 DATA13
15 R/W FLP 4 Data #14 DATA14
16 R/W FLP 4 Data #15 DATA15
17 R/W FLP 4 Data #16 DATA16
18 R/W FLP 4 Data #17 DATA17
19 R/W FLP 4 Data #18 DATA18
20 R/W FLP 4 Data #19 DATA19
21 R/W FLP 4 Data #20 DATA20