Emerson Process Management 3095FC Automobile Accessories User Manual


 
Reference Manual
00809-0100-4832, Rev AA
March 2004
C-5
Rosemount 3095FC
4 R/W BIN 1 AGA Configuration – Options:
Bit 7 – Log Methane Adjustment
0 = Yes
1 = No
Bit 6 – Heating Value
0 = Mass
1 = Volume Basis
Bit 5 – Gravitational Acceleration
0 = Calculate
1 = Enter Acceleration
Bit 4 – Heating Capacity
0 = Calculate
1 = Enter Heating Value
Bit 3 – Static Pressure Value
0 = Gauge
1 = Absolute Static Press
Bit 2 – Static Pressure Value
0 = Downstream
1 = Upstream Static Press
Bit 1 – Specific Gravity
0 = Calculate
1 = Enter Specific Gravity
Bit 0 – Tap
0 = Flange Tap
OPTION
5 R/W FLP 4 Specific Gravity SPGR
6 R/W FLP 4 Heating Value GASHV
7 R/W FLP 4 Gravity Acceleration Correction GRAVIT
8 R/O UINT 16 2 Scan Period SCANPR
9 R/W FLP 4 Pipe Diameter PIPDIA
10 R/W FLP 4 Orifice Diameter ORFDIA
11 R/W FLP 4 Orifice Measured (Reference) Temperature TMEAS
12 R/W UINT 8 1 Orifice Material OR_MAT
13 R/W AC 30 Meter Run (Point) Identification DESC
14 R/O BIN 1 Alarm Code:
Bit 7 – Manual Mode
Bit 6 – No Flow
Bit 2 – High Alarm
Bit 0 – Low Alarm
Bits 5, 4, 3, and 1 – Not Used
ALARM
15 R/W FLP 4 Low Alarm EU – Flow LOAL
16 R/W FLP 4 High Alarm EU – Flow HIAL
17 R/W FLP 4 Viscosity VISCOS
18 R/W FLP 4 Specific Heat Ratio SPHTRA
19 R/W FLP 4 BBase Pressure BASEPR
20 R/W FLP 4 Base Temperature BASETP
21 R/W FLP 4 Low Differential Pressure (hw) Cutoff MINDP
22 R/W FLP 4 Fpwl – Gravitational User Correction Factor FPWL
23 R/W FLP 4 N
2
– Nitrogen NITROG
24 R/W FLP 4 CO
2
– Carbon Dioxide CARBDI
25 R/W FLP 4 H
2
S – Hydrogen Sulfide HYDSUL
26 R/W FLP 4 H
2
O – Water WATER
27 R/W FLP 4 He – Helium HELIUM
28 R/W FLP 4 CH
4
– Methane METHAN
29 R/W FLP 4 C
2
H
6 –
Ethane ETHANE
30 R/W FLP 4 C
3
H
8
– Propane PROPAN
31 R/W FLP 4 C
4
H
10
– n-Butane NBUTAN
Parameter
Number
Read-
Write
Data Type Length Description Abbr.