Emerson Process Management 3095FC Automobile Accessories User Manual


 
Reference Manual
00809-0100-4832, Rev AA
March 2004
Rosemount 3095FC
C-4
Table C-4. Point Type – AGA Flow Parameters
16 R/O BIN 1 Alarm Code:
Bit 7 – Manual Mode
Bit 6 – Point Fail
Bit 5 – Not Used
Bit 4 – Rate Alarm
Bit 3 – High High Alarm
Bit 2 – High Alarm
Bit 1 – Low Low Alarm
Bit 0 – Low Alarm
ALARM
17 R/O INT 16 2 Raw A/D Input CURRAW
18 R/O UINT 16 2 Actual Scan Time SCAN
19 R/W FLP 4 Fault EU Value FAULTVAL
Parameter
Number
Read-
Write
Data Type Length Description Abbr.
Parameter
Number
Read-
Write
Data Type Length Description Abbr.
0 R/W AC 10 Point Tag Identification TAG
1 R/W FLP 4 Latitude LAT
2 R/W FLP 4 Elevation ELAVTN
3 R/W BIN 1 Calculation Method:
Bit 7 – Manual Mode
0 = Normal
1 = Manual
Bit 6 – RBX Set
0 = Disabled
1 = Active
Bit 5 – RBX on Clear
0 = Disabled
1 = Active
Bit 4 – ALM Enable
0 = Disabled
1 = Log Alarms
Bit 3 – US or Metric
0 = US Units
1 = Metric Units
Bit 2 – AGA3 Algorithm
1 = 1992 Algorithm
Bit 1 – Flow Calculation Method
0 = AGA3
Bit 0 – Compressibility Method
1 = AGA8
METHOD