Emerson Process Management 3095FC Automobile Accessories User Manual


 
Reference Manual
00809-0100-4832, Rev AA
March 2004
C-13
Rosemount 3095FC
Table C-12. Point Type 19 – Database Parameters
NOTE
Point Type 19 is used by Opcode 165 to configure history points and
create events.
Table C-13. Point Type 41 – Run Parameters
Parameter
Number
Read-
Write
Data Type Length Description Abbr.
0 R/O FLP 4 Pointer to Tag TAGPNTR
1 R/O UINT 8 1 Archive Type ARCHTYPE
2 R/O UINT 8 1 Point Type TYPE
3 R/O UINT 8 1 Point / Logical Number LOGICAL
4 R/O UINT 8 1 Parameter Number PARAM
5 R/O FLP 4 Yesterday’s Total YDYTOTAL
Parameter
Number
Read-
Write
Data Type Length Description Abbr.
0 R/W AC 10 Point Tag Identification TAG
1 R/W FLP 4 Atmospheric Pressure ATMPRS
2 R/W BIN 1 Calculation Method II:
Bits 7 through 5 – Not Used
Bit 4 – BTU Dry or Wet Override
0 = See Bit 3
1 = BTU as Delivered
Bit 3 – BTU Dry or Wet
0 = BTU Dry
1 = BTU Wet
Bit 2 – Calculated or Manual Value
0 = Calculated
1 = Enter Atmospheric Pressure – AGA 1992
Bit 1 – Gross Method
0 = Gross Method II
1 = Gross Method I
Bit 0 – Detail Level
0 = Detailed Method
1 = Gross Method
METHOD
3 R/O TLP 3 Not Used PIPEREFT
4 R/W FLP 4 Pipe Reference Temperature – AGA1992 PIPEMAT
5 R/W UINT 8 1 Pipe Material – AGA1992:
0 = SS (Stainless Steal)
1 = Monel
2 = Carbon steel
FB
6 R/O UINT 8 1 Not Used FR
7 R/O FLP 4 Cd – AGA 1992 FY
8 R/O FLP 4 Fr – AGA 1985
Reynolds Number – AGA 1992
FPB
9 R/O FLP 4 Y – Expansion Factor – Orifice
Fpm – Turbine
FTB
10 R/O FLP 4 Fpb Factor FPB
11 R/O FLP 4 Ftb Factor FTB
12 R/O FLP 4 Ftf Factor FTF
13 R/O FLP 4 Fgr Factor FGR
14 R/O FLP 4 Fpv – Super-compressibility Factor FPV