Emerson Process Management 3095FC Automobile Accessories User Manual


 
Reference Manual
00809-0100-4832, Rev AA
October 2004
Rosemount 3095FC
A-4
Range 4 (absolute)/ Range D (gage)
0–36.26 to 0–3,626 psi (0–2,5 to 0–250,0 bar)
(100:1 rangeability is allowed)
Accuracy (including Linearity, Hysteresis, Repeatability)
±0.075% of span for spans from 1:1 to 6:1 of URL
For spans less than 6:1 rangedown,
Ambient Temperature Effect per 50 °F (28 °C)
±(0.05% URL + 0.125% of span) spans from 1:1 to 30:1
±(0.06% URL – 0.175% of span) spans from 30:1 to 100:1
Stability
±0.125% URL for five years for ±50 °F (28 °C) ambient temperature
changes, and up to 1000 psi (6,9MPa) line pressure.
Process Temperature (RTD)
Specification for process temperature is for the transmitter portion only.
Sensor errors caused by the RTD are not included. The transmitter is
compatible with any PT100 RTD conforming to IEC 751 Class B, which has a
nominal resistance of 100 ohms at 0 °C and
= 0.00385. Examples of
compatible RTDs include the Rosemount Series 68 and 78 RTD Temperature
Sensors.
Sensing Range
–40 to 212 °F (–40 to 100 °C)
Accuracy (including Linearity, Hysteresis, Repeatability)
±1.0 °F (0.56 °C)
Ambient Temperature Effects per 50 °F (28 °C)
±0.90 °F (0.50 °C) for process temperatures from –40 to 212 °F (–40 to
100°C)
Stability
±1.0 °F (0.56 °C) for one year
Physical Specifications Electrical Connections
½–14 NPT
3
/4-14 NPT, CM 20, PG-13.5
RTD Process Temperature Input:
100-ohm platinum RTD per IEC-751 Class B
Process Connections
Transmitter: ¼–18 NPT on 2
1
/8-in. centers
RTD: RTD dependent (see ordering information)
Battery
Lead-acid
Accuracy 0.03 0.0075
URL
Span
--------------


+ % of span=