8 - 33
–+
ELEC
SIGNAL SYSTEM
2.If the reverse indicator light fails to come
on:
CONTINUITY
1.Bulb and bulb socket
● Check the bulb and bulb socket for conti-
nuity.
NO CONTINUITY
Replace the bulb and/or bulb socket.
CONTINUITY
2.Reverse switch
Refer to “SWITCH INSPECTION”.
NO CONTINUITY
Replace the reverse switch.
3.Voltage
● Connect the pocket tester (DC 20 V) to
the bulb socket leads.
Tester (+) lead → Brown terminal 1
Tester (–) lead → Green/Blue terminal 2
1
2
Br
G/Y G/Y
Br
MEETS
SPECIFICATION
● Turn the main switch to “ON”.
● Check the voltage (12 V).
This circuit is not faulty.
OUT OF SPECIFICATION
The wiring circuit from the main switch to
the bulb socket connector is faulty, repair
it.
8