Yamaha LIT-11616-12-01 Motorcycle User Manual


 
8 - 19
–+
ELEC
ELECTRIC STARTING SYSTEM
STARTER MOTOR INSPECTION
1.Inspect:
Commutator
Dirty Clean it with #600 grit sandpaper.
2.Measure:
Commutator diameter a
Out of specification Replace the starter
motor.
3.Measure:
Mica undercut b
Out of specification Scrape the mica
using a hacksaw blade.
NOTE:
Scrape the mica to the proper measure-
ment using a hacksaw blade which has
been grounded to fit the commutator.
Outside diameter:
28 mm (1.10 in)
<Wear limit:>
27 mm (1.06 in)
Mica undercut:
0.7 mm (0.028 in)
4.Inspect:
Armature coil (insulation/continuity)
Defects Replace the starter motor.
*********************************
Armature coil inspection steps:
Connect the pocket tester for the continu-
ity check 1 and insulation check 2.
Measure the armature resistances.
If the resistance is incorrect, replace the
starter motor.
*********************************
Armature coil resistance:
Continuity check 1:
0.004 ~ 0.005 at 20 ˚C (68 ˚F)
Insulation check 2:
More than 1 M at 20 ˚C (68 ˚F)