Mitsubishi Electronics MDAX520-0.5K TO 3.5K Automobile Accessories User Manual


 
8 PARAMETER FUNCTIONS
8-7
8
Using Pr. 173 to Pr. 176, register or delete the parameters to the user groups.
Pr. Setting Range Description
173 0 to 999 The parameter number to be registered is written as a set value.
0 to 999 The parameter number to be deleted is written as a set value.
User
group 1
174
9999 Written when the registered parameters are all to be deleted.
175
0 to 999
The parameter number to be registered is written as a set value.
0 to 999 The parameter number to be deleted is written as a set value.
User
group 2
176
9999 Written when the registered parameters are all to be deleted.
Key operation method (when registering Pr. 1 to the user group [Section 8.5.1])
SET
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
SET
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
Press for 2s.
Read Pr. 173.
parameter.
and perform similar operation.)
alternately.
Appear
registered appears.
The number of parameters
to be registered.
Display the parameter
Choose the next
(To make deletion, read Pr. 174
MEMO
The Pr. 77, Pr. 160 and Pr. 991 values can always be accessed for read and write
independently of the Pr. 160 setting.
"0" set in the second digit of the two-digit Pr. 160 setting is not displayed. However,
it is displayed when "0" is set in the first digit only.
Initial value
Pr. 199 "user's initial value setting" 0
You can change the initial parameter values from the factory settings to user settings. These values
may be set to 16 parameters.
By performing user clear operation from the operation panel or FR-PU04 parameter unit, you can
change the parameters to the user-set initial values.
Setting Range Description
0 to 999
The parameter number whose initial value is to be changed to a user-set value
is written.
9999 The registered user initial values are batch-deleted.
Key operation method (when registering Pr. 7 [Section 8.5.2])
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
SET
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
SET
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
SET
Press for 2s.
Read Pr. 199.
Press for 2s.
Display the parameter
Appear
alternately.
Choose the
next parameter.
The number of parameters
registered appears. to be registered.
MEMO
Each of the initial values of Pr. 902 to Pr. 905 [Section 8.3.1] uses the area of two
parameters for registration.
You cannot change the initial values of the parameters which cannot be cleared.