8 PARAMETER FUNCTIONS
8-17
8
Initial value
Pr. 904 "speed setting current bias" Approx. 20/0
Pr. 905 "speed setting current gain" Approx. 100/2000
You can set the relationship between the magnitude of the speed setting analog current signal input
to the terminal 4 and the motor speed. 0mA of the speed setting signal corresponds to approx. 0%,
and 20mA to approx. 100%.
Setting Range
Pr.
Motor speed Unit
Speed setting
signal
Unit
904 0 to 2000
0.0 to 300.0
905 1 to 3000
r/min
0.0 to 300.0
%
You can set these parameter values as when you set the speed setting voltage bias and gain in
Pr. 902 and Pr. 903.