Mitsubishi Electronics MDAX520-0.5K TO 3.5K Automobile Accessories User Manual


 
5. OPERATION
5-3
5
5.3 Operation Examples
5.3.1 PU operation mode
(1) When performing operation by setting the running speed (1000r/min) with the
(UP/DOWN) key
Step Operation Procedure (from Factory Setting)
Display
(on Completion of
Operation)
1) When power is switched on, the "MON" mode indicator
LED of the operation panel is lit and the monitor screen
appears.
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
1. Confirm the
operation mode.
2) Choose PU operation on the operation mode screen
and set 1 in Pr. 79 [Section 8.2] in the parameter setting
mode.
(When Pr. 79=0, the drive unit is placed in the external
operation mode at power-on. Therefore, you need to
change the external operation mode to the PU
operation mode every time power is switched on.)
Selecting the PU operation mode lights up the "PU"
mode indicator LED of the operation panel.
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
1) Press the
MODE
key to display the speed setting mode
screen.
2. Set the running
speed.
2) Set the running speed with the key.
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
1) Press the FWD key to start the motor running in the
forward rotation direction or the
REV
key to start it
running in the reverse rotation direction, increasing the
speed in accordance with the preset acceleration time.
2) The display screen changes automatically from the
speed setting mode screen to the monitor mode screen.
The "FWD" mode indicator LED flickers to indicate
forward rotation, or the "REV" mode indicator LED
flickers to indicate reverse rotation.
3. Enter the start
signal.
3) Acceleration is complete when the main indicator LED
shows the preset speed.
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
4. Enter the stop
signal.
1) Press the
STOP/RESET
key to decelerate the motor to
a stop in accordance with the preset deceleration time.
After stopping, the "FWD" or "REV" mode indicator LED
goes off.
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
(2) When performing JOG operation by operating the keys of the operation panel
Refer to: Chapter 8, 8.6.1 JOG operation