2. INSTALLATION
2-2
2.1 Checking the Installation Environment
2.1.1 Operating environment
General operating environment
Install the unit in the following environment.
Ambience
Indoors (No corrosive gas, flammable gas, oil mist, dust and dirt
No exposure to direct sunlight. No salt.)
Ambient temperature
-10
°
C to +50
°
C (non-freezing)
Ambient humidity
90%RH or less (non-condensing)
Altitude
Maximum 1000m
Vibration
5.9m/s
2
(conformance with JIS C 0040)
CAUTION
Install the equipment on a non-flammable material. Not doing so can cause a fire.
Do not place flammable materials near the equipment. Doing so can cause a fire.
Install the unit in a load-bearing place. Not doing so can cause an accident.
Noise environment
Since drive is an electronic piece of equipment, the drive unit may malfunction if there are machines
which generate large noises (e.g. welder, power equipment) in the periphery. Fit surge suppressors,
noise filters and/or like to the noise sources, install the drive unit as far away as possible from noise
sources, or place shielding plates and the like to fully suppress noises.
CAUTION
The drive unit itself can be the source of noises. Take noise suppression measures
to prevent peripheral equipment from malfunctioning due to noises.
Refer to: Chapter 3, 3.1.2 Noises
Chapter 6, 6.3 Noise Malfunctions and Measures