8 PARAMETER FUNCTIONS
8-34
8.6 Setting of Various Operation Methods
8.6.1 JOG operation
Initial value
Pr. 15 "JOG speed" 200
Pr. 16 "JOG acceleration/deceleration time" 0.5
Pr. Setting Range Unit
15 100 to 3000 r/min
Pr. 21 = 0 0.0 to 3600
16
Pr. 21 = 1 0.00 to 360.0
s
Set the speed for JOG operation in Pr. 15, and the acceleration/deceleration time in Pr. 16.
(1) External JOG operation
Use the start signal (terminal STF, STR) to perform JOG operation.
1) Set the unit in the external operation mode.
2) Turning "ON" the JOG signal allows JOG operation to be performed with the start signal.
Pr. 20
Pr. 15
ON
ON
ON
Time
Running speed
Pr. 16
[Section 8.5.2]
JOG signal
Forward rotation STF
Reverse rotation STR
rotation
Reverse
Forward
rotation
(2) PU JOG operation
Use the FWD or
REV
key of the operation panel to perform JOG operation.
1) Set the unit in the PU operation mode and choose the PU JOG operation mode.
2) Holding down the
FWD or
REV
key enables JOG operation.
Pr. 16
Pr. 15
ON
ON
FWD
REV
Running speed
key
key
Time
Pr. 20
[Section 8.5.2]
MEMO
There will be an about 0.1s delay between a JOG command input and a motor start.
Refer to: Chapter 5, 5.3.5 Starting operation