5. OPERATION
5-4
5.3.2 External operation mode
(1) When performing operation using the analog speed command (voltage input)
Step Operation Procedure (from Factory Setting)
Display
(on Completion of
Operation)
1) When power is switched on, the "MON" mode indicator
LED of the operation panel is lit and the monitor screen
appears.
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
1. Confirm the
operation mode.
2) Choose PU operation on the operation mode screen
and set 0 or 2 in Pr. 79 [Section 8.2] in the parameter
setting mode.
Selecting the external operation mode lights up the
"EXT" mode indicator LED of the operation panel.
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
1) Turn on the start signal connected to the terminal STF
(or STR).
2. Enter the start
signal.
2) The "FWD" (or "REV") mode indicator LED flickers.
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
1) Entering the speed setting signal to the terminal 2 runs
the motor.
3. Enter the
running speed
signal.
2) The speed rises in proportion to the increase of the
speed setting signal.
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
4. Enter the stop
signal.
1) Decreasing the speed setting signal of the terminal 2
reduces the speed.
2) After the speed reaches zero, turning off the start signal
extinguishes the "FWD" or "REV" mode indicator LED.
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
MEMO
For the analog command, the motor speed varies at the change ratio (slope) of the
input signal, but it cannot vary faster than the preset acceleration or deceleration
time. To control the speed in response to the input signal's change ratio, set the
acceleration/deceleration time to "0".
You may turn the start signal on/off to start operation after entering the speed
setting signal. In this case, the motor speed rises or falls in accordance with the
preset acceleration/deceleration time.
Use Pr. 902 to 905 [Section 8.3.1] to change the relationship between the analog
speed command and motor speed.
(2) When performing JOG operation using the terminal STF, STR
Refer to: Chapter 8, 8.6.1 JOG operation