8 PARAMETER FUNCTIONS
8-57
8
Initial value
Pr. 171 "actual operation hour meter clear" 0
You can clear the actual operation time read by setting "23" in Pr. 52.
Write "0" in Pr. 171. (The parameter is factory set to "0")
MEMO
You cannot clear the cumulative energization time read by setting 20 in Pr. 52.
Initial value
Pr. 53 "level display data selection" 1
This parameter is designed for use with the FR-PU04 parameter unit (option) only. Select the data
to be displayed on the level meter of the FR-PU04.
Setting Display Data Unit Full-Scale
0 No indication
1 Motor speed r/min Value set in Pr. 55 [Section 8.7.5]
2 Motor current A Value set in Pr. 56 [Section 8.7.5]
3 Output voltage V 400V
5 Preset speed r/min Value set in Pr. 55 [Section 8.7.5]
8 Converter output voltage V 400V
9 Regenerative brake duty % Value set in Pr. 70 [Section 8.7.5]
10
Electronic overcurrent protection load
factor
% Thermal relay operation level
11 Motor current peak value A Value set in Pr. 56 [Section 8.7.5]
12 Converter output voltage peak value V 400V