Mitsubishi Electronics MDAX520-0.5K TO 3.5K Automobile Accessories User Manual


 
8 PARAMETER FUNCTIONS
8-72
APPENDIX 1 PARAMETER LIST (NUMERICAL ORDER)
Instruction
Code
Data
No. Name Setting Range
Initial
Value
Customer
Setting
read Write Extension
Refer
to
117 Station number 0 to 31 0 11 91 1
118
Communication
speed
48, 96, 192 92 12 92 1
119
Stop bit
length/data length
0, 1, 10, 11 1 13 93 1
120
Parity check
presence/absence
0, 1, 2 2 14 94 1
121
Number of
communication
retries
0 to 10, 9999 1 15 95 1
122
Communication
check time interval
0, 0.1 to 999.8,
9999
016961
123
Waiting time
setting
0 to 150,
9999
9999 17 97 1
124
CR-LF
presence/absence
selection
0, 1, 2 1 18 98 1
8-35
128
PID action
selection
0, 10, 11, 20, 21 0 1C 9C 1
129
PID proportional
band
0.1 to 1000%,
9999
100 1D 9D 1
130 PID integral time
0.1 to 3600s,
9999
11E9E1
131 Upper limit
0.0 to 100.0%,
9999
9999 1F 9F 1
132 Lower limit
0.0 to 100.0%,
9999
9999 20 A0 1
133
PID action set
point for PU
operation
0.00 to 100.0% 0 21 A1 1
134
PID differential
time
0.01 to 10.00s,
9999
9999 22 A2 1
8-45
144
Speed unit switch-
over 2
0, 1 0 2C AC 1 8-55
150
Output current
detection level
0.0 to 200.0% 150 32 B2 1
151
Output current
detection time
0.0 to 10.0s 0 33 B3 1
8-63
156
Stall prevention
operation selection
1 to 31 (odd number),
101
1 38 B8 1 8-31