5-4
Rev 4 Aug/2007
KMD 250 Pilot's Guide
Section 5
System Messages
System Messages
Message Text Description
Nav Data Referenced To
True North
This message is displayed when a user-defined magnetic variation of 0
degrees is being used for navigation data. Check Navigation Setup
Page.
Nav Data Referenced To
User-Defined Mag Var
This message is displayed when a user-defined magnetic variation is
being used for navigation data. Check Navigation Setup Page.
No Valid FIS Subscriptions This message occurs when no current FIS subscriptions are available.
FIS data will be unavailable. Check the subscription status on the Aux
Menu FIS Subscription page. Go to www.bendixking.com to purchase a
new VDL subscription. Go to www.xmradio.com/weather to purchase a
new XM subscription. This is the only indication received when an XM
subscription has expired.
Regulated 12V Out Of
Range. Switch Unit Off
The internal 12V power supply is operating outside its acceptable range.
Turn the unit off and back on. If the message persists then the unit may
need service.
Regulated 5V Out Of Range.
Switch Unit Off
The internal 5V power supply is operating outside its acceptable range.
Turn the unit off and back on. If the message persists then the unit may
need service.
Regulated 3.3V Out Of
Range. Switch Unit Off
The internal 3.3V power supply is operating outside its acceptable range.
Turn the unit off and back on. If the message persists then the unit may
need service.
Regulated 3V Out Of Range.
Switch Unit Off
The internal 3V power supply is operating outside its acceptable range.
Turn the unit off and back on. If the message persists then the unit may
need service.
Stormscope Failure The KMD 250 is unable to communicate with the Stormscope® or it has
reported a failure. See the Stormscope® page for error codes and the
Stormscope® users manual for more information.
Traffic System Failure The KMD 250 is unable to communicate with the traffic system or the
traffic system has reported a failure.
Unit Configuration Cleared
To Defaults
A problem was detected in the memory used for storing the unit configu-
ration settings. The settings have been set back to factory defaults. In
most cases the unit will need to be reconfigured by an authorized
Bendix/King installer in order to operate properly.
Unit History Data Cleared To
Defaults
A problem was detected in the memory used to store unit history informa-
tion. The memory has effect on operation, it simply means less informa-
tion will be available to the service center if the unit requires service.
Messages 8/13/07 10:01 AM Page 5-4