8 - 29
–+
ELEC
CHARGING SYSTEM
NO
YES
EAS00776
YES
NO
EAS00779
YES
NO
NOTE:
@
Make sure the battery is fully charged.
@
• Is the charging voltage within specification?
The charging circuit
is OK.
4. Stator assembly resistance
• Remove the generator cover.
• Connect the pocket tester (Ω × 1) to the sta-
tor assembly coupler as shown.
Tester positive probe
→
white
1
Tester negative probe
→
white
2
Tester positive probe
→
white
1
Tester negative probe
→
white
3
• Measure the stator coil resistances.
Stator coil resistance
0.15 ~ 0.23
Ω
at 20 °C
• Is the stator coil OK?
Replace the stator
assembly.
WWW
Ω×1
+
5. Wiring
• Check the wiring connections of the entire
charging system.
Refer to “CIRCUIT DIAGRAM”.
• Is the charging system’s wiring properly
connected and without defects?
Replace the rectifier/
regulator.
Properly connect or
repair the charging
system’s wiring.