Polaris A07MH50AX Offroad Vehicle User Manual


 
10.60
ELECTRICAL
cell battery. Readings of 1.270 or greater should be observed in
a fully charged battery. Differences of more than .025 between
the lowest and highest cell readings indicate a need to replace
the battery.
* Measurement at 80
F
NOTE: Subtract .01 from the specific gravity reading
at 40
F
Battery Load Test
NOTE: This test can only be performed on machines
with electric starters. This test cannot be performed
with an engine or starting system that is not working
properly.
A battery may indicate a full charge condition in the OCV test
and the specific gravity test, but still may not have the storage
capacity necessary to properly function in the electrical system.
For this reason, a battery capacity or load test should be
conducted whenever poor battery performance is encountered.
To perform this test, hook a multitester to the battery in the same
manner as was done in the OCV test. The reading should be 12.6
volts or greater. Engage the starter and observe the battery
voltage while cranking the engine. Continue the test for 15
seconds. During cranking the observed voltage should not drop
below 9.5 volts. If the beginning voltage is 12.6 volts or higher
and the cranking voltage drops below 9.5 volts during the test,
replace the battery.
Charging Procedure
1. Remove the battery from the ATV to prevent damage from
leaking or spilled acid during charging.
2. Charge the battery with a charging output no larger than 1/
10 of the battery's amp/hr rating. Charge as needed to raise
the specific gravity to 1.270 or greater.
3. Install battery in vehicle with positive terminal toward the
front. Coat threads of battery bolt with a corrosion resistant
dielectric grease (PN 2871329).
4. Connect battery cables.
5. After connecting the battery cables, install the cover on the
battery and attach the hold down strap.
Table 10-1: OPEN CIRCUIT VOLTAGE
STATE OF
C
HARGE
CONVENTIONAL
L
EAD - ACID
LOW MAINTENANCE
100% 12.60V 12.70V
Charged 12.40V 12.50V
75% Charged 12.10V 12.20V
50% Charged 11.90V 12.0V
25% Charged less than 11.80V Less than 11.90V
0% Charged - -
Table 10-2: SPECIFIC GRAVITY
STATE OF
C
HARGE*
C
ONVENTIONAL
L
EAD - ACID
LOW
M
AINTENANCE
100% 1.265 1.275
Charged 1.210 1.225
75% Charged 1.160 1.175
50% Charged 1.120 1.135
25% Charged less than 1.100 Less than 1.115
0% Charged - -
Battery Hydrometer (PN 2870836)
CAUTION
To prevent shock or component damage, remove
spark plug high tension leads and connect securely
to engine ground before proceeding.
WARNING
To avoid the possibility of explosion, connect
positive (red) cable first and negative (black) cable
last.