Fisher 8800A Automobile Parts User Manual


 
8-5
Specifications
Pressure Limits
Flange and wafer rated for ASME B16.5 (ANSI) Class 150, 300, and
600; DIN PN 10, 16, 25, 40, 64, and 100; and JIS 10K, 20K, and 40K.
Power Supply
External power supply required. Flowmeter operates on 9 to 32 V dc,
17.8 mA nominal, 19.0 mA maximum.
Optional LCD Indicator
Displays flow variable, percent of range, and vortex shedding frequency.
Enclosure Rating
NEMA Type 4X, CSA Type 4X, IP66.
Hazardous Locations Certifications
Factory Mutual (FM) Approvals
E5 Explosion Proof for Class I, Division 1, Groups B, C, and D.
Dust-Ignition Proof for Class II/III, Division 1, Groups E, F, and G.
Factory sealed.
I5 Intrinsically safe for use in Class I, Division 1, Groups A, B, C, and
D. Class II/III, Division 1, Groups E, F, and G. Temp. Code T4 only
when connected in accordance with Rosemount drawings
08800-0106 and 00268-0031. Non-incendive for Class I, Division 2,
Groups A, B, C, and D. Factory sealed. Entity Parameters:
V
max
= 30 V
I
max
= 300 mA
C
i
= 0.0 µF
L
i
= 20 µH.
K5 E5 and I5 combination.
V
max
= 30 V
I
max
= 300 mA
C
i
= 0.0 µF
L
i
= 20 µH.
BASEEFA/CENELEC Intrinsic Safety Certification
I1 EEx ia IIC T4 (T
amb
= -50 °C to 60 °C)
Entity Parameters:
UI= 30 V
Ii
(1)
= 300 mA
PI
(1)
= 1.3 W
C
i
= 0.0 µF
L
i
= 20 µH.
BASEEFA Type N Certification
N1 Ex nL IIC T5 (T
amb
= -40 °C to 70 °C)
42 Vdc max.
(1) Total for transmitter.