Examples: SI Units Example 1 (SI Units)
In this application, an input frequency of 80.00 Hz represents a flow
rate of 1,686.8 lpm.
Given:
•Q = flow rate
F = frequency: 80.00 Hz
K = K-factor (compensated): 10.772 (via fieldbus configuration
tool)
•C
x
= C
8
•C
8
= 4.40287E-03 (from Table 9-1 on page 9-6)
Other Conditions:
Fluid = water
Line size = 80 mm
Line pressure = 700 kPag
URV= 2,000 lpm
LRV= 0 lpm
Operating temperature = 60 °C
Equation:
Calculations:
Q
F
KC
x
×
---------------
=
Q
80.00
10.772 C
8
×
--------------------------
=
Q
80.00
10.772 0.00440287
×
-------------------------------------------
=
Q 1,686.8 lpm
=